arrow left
arrow right
  • RIDGE TOP EXTERIORS LLC Vs. MATT S TURPIN, ELISABETH PARKER SMALL CLAIMS 4 - $2,501 - $5,000 document preview
  • RIDGE TOP EXTERIORS LLC Vs. MATT S TURPIN, ELISABETH PARKER SMALL CLAIMS 4 - $2,501 - $5,000 document preview
  • RIDGE TOP EXTERIORS LLC Vs. MATT S TURPIN, ELISABETH PARKER SMALL CLAIMS 4 - $2,501 - $5,000 document preview
  • RIDGE TOP EXTERIORS LLC Vs. MATT S TURPIN, ELISABETH PARKER SMALL CLAIMS 4 - $2,501 - $5,000 document preview
  • RIDGE TOP EXTERIORS LLC Vs. MATT S TURPIN, ELISABETH PARKER SMALL CLAIMS 4 - $2,501 - $5,000 document preview
  • RIDGE TOP EXTERIORS LLC Vs. MATT S TURPIN, ELISABETH PARKER SMALL CLAIMS 4 - $2,501 - $5,000 document preview
  • RIDGE TOP EXTERIORS LLC Vs. MATT S TURPIN, ELISABETH PARKER SMALL CLAIMS 4 - $2,501 - $5,000 document preview
  • RIDGE TOP EXTERIORS LLC Vs. MATT S TURPIN, ELISABETH PARKER SMALL CLAIMS 4 - $2,501 - $5,000 document preview
						
                                

Preview

Filing # 123438263 E-Filed 03/19/2021 04:15:49 PM IN THE COUNTY COURT OF THE SIXTH JUDICIAL CIRCUIT IN AND FOR PINELLAS COUNTY, FLORIDA - CIVIL DIVISION RIDGE TOP EXTERIORS, LLC, Case No.: 2020-006863-SC a Florida limited liability company, Division: Plaintiff V MATT S. TURPIN, and ELISABETH PARKER, Defendants. i PLAINTIFF'S NOTICE OF FILING PLEASE TAKE NOTICE that Plaintiff RIDGE TOP EXTERIORS, LLC by and through the undersigned counsel, hereby files with the Court the following documents: 1. Plaintiff's Exhibit "F.001-010" to be introduced as evidence at the trial in this matter. CERTIFICATE OF SERVICE I HEREBY CERTIFY that a true and correct copy of the foregoing has been furnished by e- designation on this 19th day of March, 2021 to: and via regular U.S. Mail to Pro Se Defendants MATT S. TUPRIN and ELISABETHPARKER at 119 South Spring Blvd., Tarpon Springs, FL 34689 and via E-mail to and Cox Law, PLLC 1.. i. n By: /s/ NM Sean P. Cox, Esq. Florida Bar Number 706760 156 E. Bloomindale Ave. Brandon, FL 33511-8179 Tel: 813-685-8600 Fax: 813-685-8699 SPC/vag sean @coxlawplc.com Cc: Client vanessa @coxlawplc.com Attorney for Plaintiff RIDGE TOP EXTERIORS ***ELECTRONICALLYFILED 03/19/2021 04:15:48 PM: KEN BURKE, CLERK OF THE CIRCUIT COURT, PINELLAS COUNTY*** MIAM F , · E MIAMI-DADE COUNTY COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATIONDIVISION Miami, Florida 33175-2474 T(786) 315-2590 F(786) 315-2599 NOTICE OF ACCEPTANCE (NON Volatile Free, Inc. 19500 Janacek Court Brookfield, WI. 53045 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submittedhas been reviewed and acceptedby Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the acceptedmanner, the manufacturerwill incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within theirjurisdiction. RER reserves the right to revoke this acceptance, if it is detennined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements o f the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Volatile Free Liquid Applied Maintenance Coating System LABELING: Each unit shall bear a permanent label with the manufacturer'sname or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negativelyaffecting the perfonnance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automaticallytenninate this NOA. Failure to comply with any section of this NOA shall be cause for terminationand removal ofNOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in itsentirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspectionat the job site at the request of the Building Official. This NOA revises NOA# 16-0628.02 and consists of pages 1 through 10. The submitted documentation was reviewed bv Freddv Semino - NOA No.: 17-1227.01 MIAMI·DADE COUNTY ExpirationDate: 11/21/22 APPROVED Approval Date: 08/16/18 Page 1 of 10 paintiffs Exhibit "F.001" ROOFING COMPONENT APPROVAL Category: Roofing Sub-Categorv: Cements, Coatings & Adhesives Materials: Urethane/ Polyurea SCOPE: This approves "VFI 990, Sealguard Silicone, VFI-991 Sealguard Silicone and VFI-640-1/VFI-605-1Acrylic System as a roofmaintenance coating manufactured by Volatile Free, Inc., as described in this Notice ofAcceptance, designed to comply with the Florida Building Code, High Velocity Hurricanes Zone. TRADE NAMES OF PRODUCTS 1MANUFACTUREDOR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description VFI 990, Sealguard 5 gal or 55 gal ASTM D 6083 A silicone single component, high-solids, Manufacturing Location #1 moisture-curedelastomer moisture-cured de coating. VFI-991 Sealguard 5 gal or 55 gal ASTM D 6694 A single component, solvent-borne, Manufacturing Location #1 moisture-curedsilicone moisture-cured ds coating. VFI-640-1/VFI-605-1 5 gal or 55 gal ASTM D 6694 A premium grade water-basedelastomeric Manufacturing Location #1 coating. VFI#11 5 gal. Proprietary A two component, 1 to 1 ratio, water-based Manufacturing Location #1 epoxy primer. VFI-3600 5 gal. Proprietary A two-component 1 to 1 ratio, polyurethane basscoat. Manufacturing Location #1 VFI-607 5 gal or 55 gal Proprietary A water-borne, single component,acrylic Manufacturing Location #1 basecoat/primer. VFI-630 2 gal or 5 gal. pails TAS 139 A premium-grade white water-based elastomericmastic which cures to form a Manufacturing Location #1 seamless membrane. VFI-993 2 gal. pails TAS 139 A thick, high build, single component Manufacturing Location #1 liquid dispersion silicone sealant grade caulk. VFI-1009 5 gal or 55 gal Proprietary A concentrated cleaning agent. Manufacturing Location #2 MANUFACTURING LOCATION: 1. Brookfield, WI. 2. Tumwater, WA. NOA No.: 17-1227.01 MIAMI·DADE COUNTY ExpirationDate: 11/21/22 APPROVED Approval Date: 08/16/18 Page 2 of 10 paintiffs Exhibit "F.002" EVIDENCE SUBMITTED: Test Aeencv Test Identifier Test Specification Date Underwriter Laboratories,Inc. R19184 Classification 09/05/99 99NK25707 PRI Asphalt Technologies IRT-012-02-01 TAS 143 09/23/02 PRI ConstructionMaterials VFI-018-02-01 ASTM D 6694 / TT-C-555B 02/25/11 Technologies VFI-018-02-01 ASTM D 6694 05/16/12 VFI-027-02-01 ASTM D 6083 12/21/12 VFI-044-02-01 ASTM D 6694 / TT-C-555B 03/30/16 VFI-042-02-01 ASTM D 6694 / TT-C-555B 02/12/16 VFI-050-02-01 Proprietary 07/12/17 VFI-051-02-01 Proprietary 06/13/17 VFI-052-02-01 Proprietary 05/12/17 VFI-053-02-01 Proprietary 12/06/17 VFI-048-02-01 ASTM D 6083 01/17/18 VFI-062-02-01 TAS 139 01/17/18 NOA No.: 17-1227.01 MIAMI·DADE COUNTY ExpirationDate: 11/21/22 APPROVED Approval Date: 08/16/18 Page 3 of 10 paintiffs Exhibit "F.003" APPROVED APPLICATIONS Trade names: VFI 990 Sealguard Thickness: See System Approvals Below Specifications: ASTM D 6694 Description: A single component solventless moisture cure elastomer applied membrane applied at an application rate of; e Smooth and Granule Surface APP Modified Bitumen: After inspection and prep, prime with VFI#11, 2 part epoxy primer; max 150 sq. ft/gal: base coat VFI-990 at rate: 0.75 to 1.25 gal/sq. (Optional); use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq to seams, penetrations and fasteners if necessary, prior to basecoat step. followed by a Top coat of 0.75-1.25 gal/100 ff. Smooth and Granule Surfaced SBS Modified Bitumen: After inspectionand prep, prime with VFI#11, 2 part epoxy primer; 2 max 150 sq. ft/gal: base coat VFI-990 at rate: 0.75 to 1.25 gal/sq. (Optional); use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq to seams, penetrations and fasteners ifnecessary, prior to basecoat step. followed by a Top coat of 0.75-1.25 gal/100 fti (Smooth) BUR: After inspectionand prep, prime with VFI#11, 2 part epoxy primer; 2 max 150 sq. ft/gal: base coat VFI-990 at rate: 0.75 to 1.25 gal/sq. (Optional);use VFI- 993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq to seams, penetrations and fasteners if necessary, prior to basecoat step. followed by a Top coat of 0.75-1.25 gal/100 ff. e Single Ply PVC: After inspection and prep, clean with VFI-1009 wash, followedby VFI-11 2 part epoxy primer @ max 300 sq ft/gal. base coat VFI-990 shall be applied as follows:0.75 gal/125 gal/sq; followedby a Top coat of VFI-990 at rate 0.75-1.25 gal/sq.(Optional); use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq to seams, penetrations and fasteners if necessary, prior to basecoat step. Single Ply EPDM: After inspectionand prep, clean with VFI-1009 wash, followed by VFI-11 2 part epoxy primer @ max 300 sq ft/gal.; base coat VFI-990 shall be applied as follows: 0.75 gal/1.25 gal; Top coat VFI-990 at a rate: 0.75 to 1.2 gal/sq. (Optional); use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq to seams, penetrations and fasteners if necessary, prior to basecoat step. Single Ply Hypalon: After inspectionand prep, clean with VFI-1009 wash, followed by VFI-11 2 part epoxy primer @ max 300 sq ft/gal. base coat VFI-990 shall be applied as follows:0.75 gal/125 gal/sq; followed by a Top coat of VFI-990 at rate 0.75-1.25 gal/sq.(Optional);use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq to seams, penetrations and fasteners ifnecessary,prior to basecoat step. Wash existing membrane with VFI-1009if dirt or other material is present that will interfere with primer adhesion. Spray Applied Polyurethane Foam: After inspection and prep base coat VFI-990 shall be applied as follows:0.75 gal/125 gal/sq; followed by a Top coat of VFI-990 at rate 0.75-1.25 gal/sq. . Galvanized Metal: After inspection and prep, prime with VFI-11 2 part epoxy primer max 150 sq ft/gal: base coat VFI-990 shall be applied as follows: 0.75 gal/125 gaVsq; followed by a Top coat of VFI-990 at rate 0.75 gal/125 gal/sq. (Optional); use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq to seams, penetrations and fasteners if necessary, prior to basecoat step. NOA No.: 17-1227.01 MIAMI·DADE COUNTY ExpirationDate: 11/21/22 APPROVED Approval Date: 08/16/18 Page 4 of 10 ? " Piainriyfs Exhibit F.004 e Concrete: After inspection and prep, prime (Primer Optional); with VFI-11, 2 part epoxy primer VFI #11 @ max 300 sq ft/gal; (Optional); Base coat VFI-990 at rate of 0.75-1.25 gal/sq; followed by a Top coat of VFI-990 at rate 0.75-1.25 gal/100sq (Optional); use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq to seams, penetrations and fasteners if necessary, prior to basecoat step. Wash existing concrete with VFI-1009 if dirt or other material is present that will interfere with primer adhesion. Container Size: 5 pails, 55 gallons drums, 270 gallon totes. Note all precautions on container. SystemsApprovals: Methods of application and quantities shall comply specific Roof Assembly, Product Control Notice of Acceptance APPROVED APPLICATIONS Trade names: VFI 990 Sealguard TopCoat and VFI-3600 Basecoat Thickness: See System Approvals Below Specifications: ASTM D 6694 Description: A single component solventless moisture cure elastomer applied membrane applied at an application rate of: . Galvanized Metal: After inspection and prep, prime with VFI-11 2 part epoxy primer max 150 sq ft/gal: (Optional); base coat VFI-3600 at rate as follows: 2.00 to 2.50 gal/sq; followed by a Top coat ofVFI-990 at rate 1.25 to 1.75 gal/sq. Single Ply EPDM(aged): After inspection and prep, clean with VFI-1009 wash, followed by VFI-11 2 part epoxy primer @ max 300 sq ft/gal; (optional); base coat VFI-3600 shall be applied as follows: 2.00 to 2.50 gal/sq; followedby a Top Coat of VFI-990 at rate 1.25 to 1.75 gal/sq. e Spray Applied Polyurethane Foam: After inspection and prep., apply base coat VFI- 3600 at rate as follows: 2.00 to 2.50 gal/sq; followed by a Top coat of VFI-990 at rate 1.25 to 1.75 gal/sq. Container Size: 5 pails, 55 gallons drums, 270 gallon totes. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply specific Roof Assembly, Product Control Notice of Acceptance NOA No.: 17-1227.01 MIAMI·DADE COUNTY ExpirationDate: 11/21/22 APPROVED Approval Date: 08/16/18 Page 5 of 10 " Piainriyfs Exhibit F.005" Trade names: VFI 991 Sealguard Thickness: See System Approvals Below Specifications: ASTM D 6694 Description: A single component, solvent-based silicone moisture cure elastomeric roofing membrane applied at the following rates: Smooth and Granulated Modified Bitumen (APP and SBS) - After inspection and prep, prime with #11 @ max 150 sq. ft. /gal; base coatVFI-991 at rate: 1.00 to 1.70 gal/sq.; top coat VFI-991 at rate: 1.00 to 1.70 gal/sq. Optional, use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary,prior to basecoat step. e TPO (Aged) - After inspection and prep, clean with VFI-1009 wash; prime with #11 @ max 300 sq. ft./gal;base coat VFI-991 at rate: 1.00 to 1.70 gal/sq.; top coat VFI-991 at rate: 1.00 to 1.70 gal/sq. Optional, use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gaVsq. to seal seams, penetrations and fasteners if necessary,prior to basecoat step. e Asphaltic Built-Up Roof (Smooth) - After inspection and prep, prime with #11 @ max 150 sq. ft. /gal; base coat VFI-991 at rate: 1.00 to 1.70 gal/sq.; top coat VFI-991 at rate: 1.00 to 1.70 gal/sq. Optional, use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gaVsq. to seal seams, penetrations and fasteners if necessary,prior to basecoat step. . Galvanized Metal- After inspection and prep, prime (primer optional, only mandated for rusted metal) with #11 max 150 sq. ft./gal; base coat VFI-991 at rate: 1.00 to 1.70 gaVsq.; top coat VFI- 991 at rate: 1.00 to 1.70 gal/sq. Optional, use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary,prior to basecoat step. EPDM (Aged) - After inspection and prep, clean with VFI-1009 wash; prime with #11 @ max 300 sq. ft. /gal; base coat VFI-991 at rate: 1.00 to 1.70 gal/sq.; top coat VFI-991 at rate: 1.00 to 1.70 gal/sq. Optional, use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. Hypalon/CSPE (Aged) - After inspection and prep, clean with VFI-1009 wash; prime with #11 @ max 300 sq. ft. /gal; base coat VFI-991 at rate: 1.00 to 1.70 gal/sq.; top coat VFI-991 at rate: 1.00 to 1.70 gal/sq. Optional, use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. e PVC (Aged) - After inspection and prep, clean with VFI-1009 wash; prime with VFI-#11 @ max 300 sq. Et/gal; base coat VFI-991 at rate: 1.00 to 1.70 gal/sq.; top coat VFI-991 at rate: 1.00 to 1.70 gal/sq. Optional, use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. SPUF-Afterinspectionand prep, base coat VFI-991 at rate: 1.00 to 1.70 gal/sq.; top coat VFI-991 at rate: 1.00 to 1.70 gal/sq. Optional, use VFI-993 flashing grade silicone caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. NOA No.: 17-1227.01 MIAMI·DADE COUNTY ExpirationDate: 11/21/22 APPROVED Approval Date: 08/16/18 Page 6 of 10 " Piainriyfs Exhibit F.006" Container Size: 5 pails, 55 gallons drums, 270 gallon totes. Note all precautions on container. SystemsApprovals: Methods of application and quantities shall comply specific Roof Assembly, Product Control Notice of Acceptance Trade names: VFI-991 Sealguard Topcoat and VFI-640-1 Basecoat Thickness: See System Approvals Below Specifications: ASTM D 6694 e Granulated Modified Bitumen (SBS) - After inspectionand prep, prime with either VFI-607 @ max 1.6 gal/sq. or #11 @ max 150 sq. ft. /gal; base coat VFI-640-1 at rate: 1.50 to 3.00 gal/sq.; top coat VFI-991 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary,prior to basecoat step. I Smooth Modified Bitumen (APP) - After inspectionand prep, prime with #11 @ max 150 sq. ft. /gal; base coat VFI-640-1 at rate:1.50 to 3.00 gal/sq.; top coat VFI-991 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary,prior to basecoat step. e TPO (Aged)- After inspection and prep, clean with VFI-1009 wash; base coat VFI-640-1 at rate: 1.50 to 2.70 gal/sq.; top coat VFI-991 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. e Asphaltic Built-Up Roof (Smooth)- After inspectionand prep, prime with VFI-607 @ max 1.6 gal/sq. (optional); base coat VFI-640-1 at rate:1.50 to 3.00 gal/sq.; top coat VFI-991 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. e Galvanized Metal- After inspection and prep, prime (primer optional, only mandated for rusted metal) with #11 max 150 sq. Et/gal; base coat VFI-640-1 at rate: 1.50 to 2.70 gal/sq.; top coat VFI-991 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary prior to basecoat step. yp e Concrete - After inspection and prep, base coat VFI-640-1 at rate:1.50 to2.70 gal/sq.; top coat VFI-991 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq.to seal seams, penetrations and fasteners if necessary,prior to basecoat step. e EPDM (Aged)- After inspection and prep, clean with VFI-1009 wash; base coat VFI-640-1 at rate: 1.50 to 2.70 gal/sq.; top coat VFI-991 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. NOA No.: 17-1227.01 MIAMI·DADE COUNTY ExpirationDate: 11/21/22 APPROVED Approval Date: 08/16/18 Page 7 of 10 ? ,, Piainriyfs Exhibit F.007 e Hypalon/CSPE (Aged) - After inspection and prep, clean with VFI-1009 wash; prime with #11 @ max 300 sq. ft./gal (optional); base coat VFI-640-1 at rate:1.50 to 2.70 gal/sq.; top coat VFI- 991 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. e PVC (Aged)- After inspection and prep, clean with VFI-1009 wash; base coat VFI-640-1 at rate: 1.50 to 2.70 gal/sq.; top coat VFI-991 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. e Liquid Applied SPUF-Afterinspection and prep, base coat VFI-640-1 at rate: 1.50 to 2.70 gal/sq; top coat VFI-991 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq to seal seams, penetrations and fasteners if necessary, prior to basecoat step Container Size: 5 gallon pails, 55 gallon drums, 270 gallon totes. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with specific Roof Assembly, Product Control Notice of Acceptance. Trade names: VFI 605-1 and VFI-640-1 Specifications: ASTM D 6083 Description: A single component, acrylic roofing membrane applied at the following rates: . Granulated Modified Bitumen (SBS) - After inspection and prep, prime with VFI-607 @ max 1.6 gal/sq. or #11 @ max 150 sq. ft./gal; base coat VFI-640-1: rate of 1.50 to 3.00 gal/sq.; top coat VFI-605-1: rate of 1.25 to 2.25 gaVsq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gaVsq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. . Smooth Modified Bitumen (APP) - After inspection and prep, prime with #11 @ max 150 sq. ft./gal; base coat VFI-640-1: rate of 1.50 to 3.00 gal/sq.; top coat VFI-605-1: rate of 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. e TPO (Aged)- After inspectionand prep, clean with VFI-1009 wash; no primer; base coat VFI- 640-1 at rate:1.50 to 2.70 gal/sq.; top coat VFI-605-1 at rate:1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners ifnecessary, prior to basecoat step. e Asphaltic Built-Up Roof (Smooth) - After inspectionand prep, prime with VFI-607 @ max 1.6 gal/sq. (optional); base coat VFI-640-1 at rate:1.50 to 3.00 gal/sq.; top coat VFI-605-1 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. NOA No.: 17-1227.01 MIAMI·DADE COUNTY ExpirationDate: 11/21/22 APPROVED Approval Date: 08/16/18 Page 8 of 10 paintiffs Exhibit "F.008" . Galvanized Metal - After inspection and prep, prime (primer optional,only mandated for rusted metal) with #11 max 150 sq. ft./gal; base coat VFI-640-1 at rate:1.50 to 2.70 gal/sq.; top coat VFI-605-1 at rate of 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gaVsq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. e Concrete - After inspection and prep, base coat VFI-640-1 at max rate: 1.50 to 2.70 gal/sq.; top coat VFI-605-1 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gaVsq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. e EPDM (Aged)- After inspection and prep, clean with VFI-1009 wash; base coat VFI-640-1 at rate: 1.50 to 2.70 gal/sq.; top coat VFI-605-1 at rate:1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gaVsq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. Hypalon/CSPE (Aged) - After inspectionand prep, clean with VFI-1009 wash; prime with #11 @ max 400 sq. ft. /gal; base coat VFI-640-1 at rate: 1.50 to 2.70 gal/sq.; top coat VFI-605- 1 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. e PVC (Aged)- After inspectionand prep, clean with VFI-1009 wash; base coat VFI-640-1 at rate: 1.50 to 2.70 gal/sq.; top coat VFI-605-1 at rate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gaVsq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. e SPUF-After inspection and prep, base coat VFI-640-1 at rate:1.50 to 2.70 gal/sq.; top coat VFI-605-1 atrate: 1.25 to 2.25 gal/sq. Optional, use VFI-630 flashing grade acrylic caulk at 0.75 to 2.00 gal/sq. to seal seams, penetrations and fasteners if necessary, prior to basecoat step. Container Size: 5 gallon pails, 55 gallon drums, 270 gallon totes. Note all precautions on container. SystemsApprovals: Methods of application and quantities shall comply with specific Roof Assembly, Product Control Notice of Acceptance. NOA No.: 17-1227.01 MIAMI·DADE COUNTY ExpirationDate: 11/21/22 APPROVED Approval Date: 08/16/18 Page 9 of 10 " Piainriyfs Exhibit F.009" LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire rating of this product. 2. VFI 990, Sealguard Silicone, VFI-991 Sealguard Silicone and VFI-640-1/VFI-605-1Acrylic System shall not be applied in inclementweather conditions. 3. VFI 990, Sealguard Silicone, VFI-991 Sealguard Silicone and VFI-640-1/VFI-605-1Acrylic System shall not be applied over asphaltic shingles, metal shingles, fiber-cement shingles, quarry slate, cement or clay roofing tile, or wood shingles or shakes. 4. The products listed herein are components of roofassemblies and are approved for use with roofassemblies that list any of the products listed herein as part of their roof assemblies Notice of Acceptance. For applications over existing single ply, smooth or granulated BUR systems. Refer applicable building code for requirements. 5. All products listed herein shall have an unannounced follow-up quality control program from an approvedlisting agency. Follow up test results shall be made available to RER upon request. 6. All approved products listed herein shall be labeled in compliance with TAS 121. 7. Change in materials, use, or manufacture of any of the products listedherein shall be cause for tenninationof this Notice of Acceptance 8. VFI 990, Sealguard Silicone, VFI-991 Sealguard Silicone and VFI-640-1/VFI-605-1Acrylic System Sealguard shall only be applied by a factory trained and certified applicators 9. VFI 990, Sealguard Silicone, VFI-991 Sealguard Silicone and VFI-640-1/VFI-605-1Acrylic System shall be applied in accordance with manufacturer' s published application instructions 10. The use of a reinforcing fabric in a maintenance coating is only to enhance the coatings ability to deliver efficient and long term perfonnance through the protection of the underlying roof system and in this particular use does not become a roof system itself 11. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 12. All packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below MIAMI·DADE COUNTY APPROVED END OF THIS AcCEPTANCE NOA No.: 17-1227.01 MIAMI·DADE COUNTY ExpirationDate: